General Specifications
|
|
Measuring Range on
1 Meter Path
|
From 0-200 mg/m
3
up to 0-4000 mg/m
3
Calibrated to VDI 2066
|
|
Light Source
|
Super Broadband LED
|
|
Measuring Range:
|
|
Optical
Density
|
From 0.1 up to 1.6 Extinction
|
|
Opacity
|
From 20%-100% range switching
|
|
Measurement Path Length
|
0.5-12 meters
|
|
Output Signal
|
2x 0-20 mA; live zero 4 mA
|
|
Maximum Load
|
500 ohms
|
|
Bus Interface for
Programming and Results
|
Modbus, CAN bus
|
|
Relay Outputs
|
All contacts are voltage-free,
6x status for limit value, failure,
control cycle, etc.
|
|
Maximum Switching Cap
|
250 V, 100 VA
|
|
Inputs
|
6x status for input enable, 2x range selection,
failure purge air, control cycle
|
|
Output Signal Integration Time
|
10-1800 seconds, freely programmable
|
|
Temperature ranges
|
|
Permissible Ambient Temp.
|
253-323 K
|
|
Flue Gas Temperature
|
Above dew point
|
|
Electrical Data
|
|
Power Supply
|
90-264 V, 48-62 Hz
|
|
Power Consumption
|
Approx. 30 W
|
|
Mechanical Data
|
|
Protection Class
|
IP65/NEMA 4x
|
|
Weights
|
Measuring head: approx. 10 kg
Reflector: approx. 7 kg
|
|
Data on Purge Air Unit
|
|
Power Supply
|
115/230 V. 50 Hz. 0.37 KW
115/230 V. 60 Hz. 0.43 KW
|
|
Blower Output
|
Approximately 80-90 m
3
/hour
|
|
Measurements
|
14x22x20 inches (350x550x500 mm)
|
|
Weight
|
Approximately 12 kg
|