Gas Burners

Heat release max. 2000 kW

  • Guaranteed electromagnetic compatibility
  • No high-voltage cable required on site
  • Protection ratings of IP 54 (standard) or IP 65 (special version)
  • Rugged, low-maintenance design
  • Service friendly design: All electrical components are easy to replace
  • Nine burner sizes ranging from 15 kW to 4.5 MW (50,000 BTU/hr to 15,000,000 BTU/hr)
  • Built-in flame rod, ideally located
  • EC-approved ionisaton flame monitors and burner controls
  • Fuel types include natural gas, conditioned coke oven gas, propane/butane or process gas, according to customer preference and analysis
  • 1-stage, 2-stage or modulated operation
  • Wide turn down ratio
  • Custom outer tube lengths available in 10-mm increments

Applications

  •     Steel industry
  •     Light metal industry
  •     Brick and ceramic industries
  •     Process applications (chemical, refinery)

Approvals

(*) Certifications of the integrated ionisation flame monitor

(*) Certification of the integrated burner control

 

Certifications of the integrated ionisation flame monitors (*):

(*) Option: Main flame monitor may be provided by client

Certifications of the integrated ionisation flame monitor (*):

(*) Main flame monitor may be provided by client

Technical Data

800 kW2000 kW3200 kW
Data
Outer tube diameter160 mm220 mm275 mm
Turn down ratio 10 : 110 : 1-
Outer tube length 360 – 4000 mm360 – 4000 mm-
Gas port Rp 2, top or bottomRp 2, bottom-
Air portDN 100 / PN 6, rotatable 4 x 90°DN 150 / PN 16, rotatable 4 x 90°-
Power head
Ignition 2 x 5 kV against ground2 x 5 kV against ground-
Ambient temperature- 30 °C to + 60 °C
(BA4/BDA4)
- 30 °C to - 85 °C (BR4/BD4)
- 30 °C to + 60 °C
(BA5/BDA5)
- 30 °C to - 85 °C (BR5/BD5)
-
Protection ratingIP54/IP65IP54/IP65-
Models
with integrated spark transfomer and ionisation flame monitor for intermittent operationBA4...BA5...-
with integrated spark transfomer and ionisation flame monitor for continuous operationBDA4...BDA5...-
with integrated spark transfomer and burner control for intermittent operation BR4...BR5...-
with integrated spark transfomer and burner control for continuous operationBD4...BD5...-
Heat release--3.2 MW
Ignition / pilot--ZDA0
Main flame supervision--Ionisation / UV

Certificates

The certificates are available for logged-in partners only.

Your contact options

Email

Contact

Sales

Sales

Service

Service