Gas Burners

Heat release max. 35 kW

  • Guaranteed electromagnetic compatibility
  • No high-voltage cable required on site
  • Protection ratings of IP 54 (standard) or IP 65 (special version)
  • Rugged, low-maintenance design
  • Service friendly design: All electrical components are easy to replace
  • Nine burner sizes ranging from 15 kW to 4.5 MW (50,000 BTU/hr to 15,000,000 BTU/hr)
  • Built-in flame rod, ideally located
  • EC-approved ionisaton flame monitors and burner controls
  • Fuel types include natural gas, conditioned coke oven gas, propane/butane or process gas, according to customer preference and analysis
  • 1-stage, 2-stage or modulated operation
  • Wide turn down ratio
  • Custom outer tube lengths available in 10-mm increments

Applications

  •     Steel industry
  •     Light metal industry
  •     Brick and ceramic industries
  •     Process applications (chemical, refinery)

Approvals

(*) Certifications of the integrated ionisation flame monitor

(*) Certifications of the integrated burner control

 

Certifications of the integrated ionisation flame monitor (*):

(*) Option: Main flame monitor may be provided by client

Certifications of the integrated ionisation flame monitor (*):

(*) Main flame monitor may be provided by client

Technical Data

15 kW35 kW35 kW
Data
Outer tube diameter35 mm50 mm50 mm
Turn down ratio 5 : 110 : 110 : 1
Outer tube length 240 – 4000 mm240 – 4000 mm200 – 4000 mm
Gas port Rp 1/2, left or rightRp 1/2, left or rightRp 3/4, rotatable 4 x 90°
Air portRp 1, rotatable 4 x 90°Rp 1, rotatable 4 x 90°Rp 1 1/2, rotatable 4 x 90°
Power head
Ignition 5 kV against ground5 kV against ground5 kV against ground
Ambient temperature- 30 °C to + 60 °C- 30 °C to + 60 °C- 30 °C to + 60 °C (BA0/BDA0)
- 30 °C to + 85 °C (BR0/BD0)
Protection ratingIP54/IP65IP54/IP65IP54/IP65
Models
with integrated spark transfomer and ionisation flame monitor for intermittent operationBAKP...BAK0...BA0...
with integrated spark transfomer and ionisation flame monitor for continuous operationBDAKP...BDAK0...BDA0...
with integrated spark transfomer and burner control for intermittent operation --BR0...
with integrated spark transfomer and burner control for continuous operation--BD0...