Gas Fired Igniters

Heat release max. 120 kW

  • Compact design with integrated spark transformer and ionisation flame monitor/burner control
  • Built-in flame rod, ideally located
  • No high-voltage cable required on site
  • Guaranteed electromagnetic compatibility
  • Rugged, low-maintenance design
  • Sizes ranging from 2 kW to 10 MW (7,000 BTU/hr to 35,000,000 BTU/hr)
  • Custom outer tube lengths available in 10-mm increments
  • Fuel types include natural gas, conditioned coke oven gas, propane/butane or process gas, according to customer preference and analysis
  • Extremely tight and long pilot flame - no automatic retraction system typically required
  • Class 1, 2 or 3 gas fired igniters according to NFPA also available
  • Also available with flexible outer tube for tilting burners

Applications

  • Ignition of medium-sized gas and oil burners in industrial furnaces and boilers

Approvals

(*) Certifications of the integrated ionisation flame monitor

(*) Certifications of the integrated ionisation flame monitor

(*) Certifications of the integrated ionisation flame monitor

Technical Data

45 kW120 kW250 kW
Common data
Outer tube diameter35 mm48 / 50 mm (50 mm material stainless steel)Outer tube length up 65 / 70 mm (70 mm material stainless steel)
Flame length (depending on the gas)max. 500 mmmax. 600 mmmax. 1200 mm
Outer tube length L240 - 15000 mm240 - 15000 mm240 - 15000 mm
Gas portRp 1/2, left or rightRp 1/2, left or rightRp 3/4, top or bottom
Gas pressure inlet 50 - 150 mbarg50 - 150 mbarg50 - 150 mbarg
Air portRp 1, rotatable 4 x 90°Rp 1, rotatable 4 x 90°Rp 1½, rotatable 4 x 90°
Air pressure operating ≥15 mbarg depending on the outer tube length≥10 mbarg depending on the outer tube length≥10 mbarg depending on the outer tube length
Power head (not ZGP/ZG0/ZG1)
Ignition5 kV against ground5 kV against ground5 kV against ground
Ambient temperature- 30 °C to + 60 °C- 30 °C to + 60 °C- 30 °C to + 60 °C
Protection ratingIP 54 or IP 65IP 54 or IP 65IP 54 or IP 65
Models
without electrical componentsZGP...ZG0...ZG1...
with integrated spark transformerZTP...ZT0...ZT1...
with integrated spark transformer and ionisation flame monitor for intermittent operationZAP...ZA0...ZA1...
with integrated spark transformer and ionisation flame monitor for continuous operationZDAP...ZDA0...ZDA1...
with integrated spark transformer and burner control for intermittent operationZR1...
with integrated spark transformer and burner control for continuous operationZD1...

Your contact options

Email

Contact

Sales

Sales

Service

Service