Gas Fired Igniters

Heat release max. 2000 kW

  • Compact design with integrated spark transformer and ionisation flame monitor/burner control
  • Built-in flame rod, ideally located
  • No high-voltage cable required on site
  • Guaranteed electromagnetic compatibility
  • Rugged, low-maintenance design
  • Sizes ranging from 2 kW to 10 MW (7,000 BTU/hr to 35,000,000 BTU/hr)
  • Custom outer tube lengths available in 10-mm increments
  • Fuel types include natural gas, conditioned coke oven gas, propane/butane or process gas, according to customer preference and analysis
  • Extremely tight and long pilot flame - no automatic retraction system typically required
  • Class 1, 2 or 3 gas fired igniters according to NFPA also available
  • Also available with flexible outer tube for tilting burners

Applications

  • Igniter and pilot burner for lean gas burners, heavy fuel oil burners or warm-up burners

Approvals

(*) Certifications of the integrated ionisation flame monitor

(*) Certifications of the integrated ionisation flame monitor

(*) Certifications of the integrated ionisation flame monitor

Technical Data

600 kW1000 kW2000 kW
Common data
Outer tube diameter90 mm135 mm160 mm
Flame length (depending on the gas)max. 2000 mmmax. 2000 mmmax. 2000 mm
Outer tube length L240 - 10000 mm300 - 10000 mm300 - 4000 mm
Gas portRp 1, top or bottomRp 2, top or bottomRp 2, top or bottom
Gas pressure inlet 50 - 150 mbarg50 - 150 mbarg50 - 150 mbarg
Air portRp 2, rotatable 4 x 90°DN 80 / PN 6, rotatable 4 x 90°DN 100 / PN 6, rotatable 4 x 90°
Air pressure operating ≥10 mbarg depending on the outer tube length≥10 mbarg depending on the outer tube lengthmin. 5 mbarg, depending on the outer tube length
Power head (not ZG2/ZG3/ZG4)
Ignition2 x 7,5 kV, ignition electrode against ignition electrode2 x 5 kV, ignition electrode against ignition electrode2 x 5 kV, ignition electrode against ignition electrode
Ambient temperature- 30 °C to + 60 °C- 30 °C to + 60 °C- 30 °C to + 60 °C
Protection ratingIP 54 or IP 65IP 54 or IP 65IP 54 or IP 65
Models
without electrical componentsZG2...ZG3...ZG4...
with integrated spark transformerZT2...ZT3...ZT4...
with integrated spark transformer and ionisation flame monitor for intermittent operationZA2...ZA3...ZA4...
with integrated spark transformer and ionisation flame monitor for continuous operationZDA2...ZDA3...ZDA4...
with integrated spark transformer and burner control for intermittent operationZR2...ZR3...ZR4...
with integrated spark transformer and burner control for continuous operationZD2...ZD3...ZD4...

Your contact options

Email

Contact

Sales

Sales

Service

Service