Tube Ø54 mm explosionproof

Gas Fired Igniters

Ignition of main burners in furnaces, boilers, power plants and incinerators.

Overview

  • High energy ignition, Insensitive to moisture
  • Material burner tube stainless steel 310
  • Material connection enclosure stainless steel 316
  • Self-aspirating, forced air supply or combination
  • For self-aspirating version no air supply line required
  • Insensitive to pressure fluctuations (draft and windbox)
  • Integrated spark plug and ionisation electrode
  • Explosion proof ATEX II 2G Ex e IIC T6/T5 Gb/-, DEKRA 11ATEX 0032; IECEx DEK 11.0010
  • Option for ATEX II 2G Eex d IIC T6 PTB 03 ATEX 1190, GOST R execution
  • Min. and max. temperature for connection enclosure: -40 to 80 °C, IP66
  • Electrical connection, 2 x M20x1,5 mm cable gland
  • Connection to main burner: 2 1/2" Ansi 150 LBS RF - Gas connection: ½" NPTF

Applications

  • Main burners of furnaces, boilers, incinerators and power plants

Technical Data

Explosion proof self-aspirating ignition burner
type54AVD13-L-A-VE54AV13EXE-L-A-V2E54AVD13-L-A-V2E54AVD13-L-A-V5E
heat release with natural gas46–75 kW80–132 kW80–132 kW185–305 kW
heat release with propane67–109 kW120–195 kW120–195 kW280–458 kW
min. max pressure0,5 - 1,5 Barg0,5 - 1,5 Barg0,5 - 1,5 Barg0,5 - 1,5 Barg
length L400, 500, 600: multiple of 100 mm, from 1000 to 2000 mm: 200 mm intervals 2000, 2500, 3000 mm400, 500, 600: multiple of 100 mm, from 1000 to 2000 mm: 200 mm intervals 2000, 2500, 3000 mm400, 500, 600: multiple of 100 mm, from 1000 to 2000 mm: 200 mm intervals 2000, 2500, 3000 mm400, 500, 600: multiple of 100 mm, from 1000 to 2000 mm: 200 mm intervals 2000, 2500, 3000 mm
air inlet A165, 230 or 400 mm in steps of 10 mm165, 230 or 400 mm in steps of 10 mm165, 230 or 400 mm in steps of 10 mm165, 230 or 400 mm in steps of 10 mm
connection to main burnerflange 2½“ ANSI 150 LBS RFflange 2½“ ANSI 150 LBS RFflange 2½“ ANSI 150 LBS RFflange 2½“ ANSI 150 LBS RF
gas connection½“ NPTF½“ NPTF½“ NPTF½“ NPTF
air conn. for forced draft½“ BSPF½“ BSPF½“ BSPF½“ BSPF
ignition3 integrated spark plugs3 integrated spark plugs3 integrated spark plugs3 integrated spark plugs
flame detectionIonisationIonisationIonisationIonisation
tube material310 SST310 SST310 SST310 SST
connection material316 SST316 SST316 SST316 SST
electrical connectionexplosion proof connection housingexplosion proof connection housingexplosion proof connection housingexplosion proof connection housing
protectionIP65IP66IP65IP65
protectionATEX II G EEx D IIC T6ATEX II G EEx D IIC T6ATEX II G EEx D IIC T6ATEX II G EEx D IIC T6

Your contact options

Email

Contact

Sales

Sales

Service

Service