Plasma Ignition System

  • Safe ignition of different gaseous, liquid and solid fuels
  • Familiar high reliability
  • High ignition potential: high temperature with high energy density in the ignition volume
  • No fuel and no combustion air required
  • Creation of plasma with variable carrier media possible (e.g. air)
  • Easy and simple integration in superordinate control Systems
  • Low requirement for maintenance
  • Few connections and interfaces required

Applications

The Plasma Ignition System is usable for ignition of difficult to be ignited fuels like pulverized solid fuels (pre-dried lignite (PDL), hard coal and biomass) as well as gases, oils and special fuels. Additionally the igntion in low-oxygen or oxygen-free atmospheres is possible.

The firing systems can be found in the following areas:

  • Fossil-fired power plants (lignite, hard coal, biomass, oil and gas)
  • Thermal process utilities (industrial ovens)
  • Chemical palnts
  • Timber industry
  • Waste incinerators
  • Petrochemical industry
  • Iron and steel industry

 

 

Technical Data

1 kW3 kW
Plasma Jet length (typical)100 mm150 mm
Plasma temperatureapprox. 3500 °Capprox. 3500 °C
Lance diameter28 mm35 mm
Protection classIP 65IP 65
Ambient temperature lance head0 °C ... 60 °C0 °C ... 60 °C
Operational temperature plasma lance (continuously) 180 °C180 °C
Operational temperature tip of lance (max. 2 min. without additional air or water cooling)max. 1100 °Cmax. 1100 °C
MaterialStainless steelStainless steel
Length of lancemax. 3 m max. 5 m
Power supply230 VAC400 VAC
Carrier mediume.g. compressed aire.g. compressed air

Your contact options

Email

Contact

Sales

Sales

Service

Service