D-FS2
Furnace Sensor
The digital furnace sensor D-FS2 delivers high definition live images directly out of the combustion chamber.
The D-FS2 VIS with high resolution colour video is available as water or air cooled version.
The furnace sensor D-FS2 is designed for the use with a retraction unit. All versions can be extended with the D-VTA 200 software to a thermography and analysis system.
Overview
- Digital (GigE) video output
- Water or air cooled for up to 2000°C in the combustion chamber
- Angled version available
- Special endoscope with high optical resolution
- Different lengths and field of views available
- For integration in the D-VTA 200 Thermography Analysis System
Your Benefit
- Brilliant live images
Special endoscope delivers the image in high resolution out of the combustion chamber to a modern digital camera - live video in real-time
- Detection of radiation changes
Due to the manually, remotely controlled exposure time radiation changes of the process or the flame can be detected immediately
- High availability
The furnace sensor is designed to be inserted continuously (24/7) in the combustion chamber
- Safe and reliable
In case of cooling or power failure the optional retraction unit will automatically retract the furnace sensor
- Flexible system
Optional upgrade with thermography and analysis modules, adaptation to the application possible
Applications
- Power stations
- Chemical industry
- Refineries
- Cement plants
- Waste incinerators
Technical Data
Video system Resolution GigE (Standard) | 1280x960@40f/sec |
Temperature measurement range with D-VTA 200 software | 800°C - 2000°C |
Weight D-FS2 ...W70-700 D-FS2 ...A60-700 | app. 14kg app. 12kg |
Maximum temperature in combustion chamber D-FS2 ... W70-xxxx D-FS2 ... A60-xxxx | up to 2000°C up to 1600°C |
Temperature monitoring at endoscope tip | PT100 |
Ambient temperature (operational) | -30 ... +60°C |
Furnace pressure | -100 ... +100mbar |
Cooling media (water cooled version) cooling water quantity purge air quantity | >500l/h >15Nm3/h |
Cooling media (air cooled version) cooling air quantity purge air quantity | >35Nm3/h >15Nm3/h |
IP protection class (IEC 60529) | IP66 |
Subject to technical modifications.
Video system Resolution Ethernet | 320x240@30f/sec |
Measurement range with D-VTA 200 software | 250°C - 1200°C |
Weight D-FS2 ...W70-700 D-FS2 ...A60-700 | app. 14kg app. 12kg |
Maximum temperature in combustion chamber D-FS2 ... W70-xxxx D-FS2 ... A60-xxxx | up to 2000°C up to 1400°C |
Temperature monitoring at endoscope tip | PT100 |
Maximum ambient temperature | -30 ... +60°C |
Furnace pressure | -100 ... +100mbar |
Cooling media (water cooled version) Amount of cooling water Amount of purge air Air for Vortex cooler | >500l/h >15Nm3/h 15Nm3/h |
Cooling media (air cooled) Amount of cooling air Amount of purge air Air for Vortex cooler | >35Nm3/h >15Nm3/h 15Nm3/h |
IP-Rating | IP66 |
Accessories
- Retraction unit (D-RU2 A60/W70)
- Sensor control unit for power supply and signal transmission (D-SCU xx)
- Welding plate for retraction unit
- Mounting flange for fixed installation without retraction unit
- Two stage air filter system for purge and cooling air