Gas Fired Igniters

Heat release max. 120 kW

  • Compact design with integrated spark transformer and ionisation flame monitor/burner control
  • Built-in flame rod, ideally located
  • No high-voltage cable required on site
  • Guaranteed electromagnetic compatibility
  • Rugged, low-maintenance design
  • Sizes ranging from 2 kW to 10 MW (7,000 BTU/hr to 35,000,000 BTU/hr)
  • Custom outer tube lengths available in 10-mm increments
  • Fuel types include natural gas, conditioned coke oven gas, propane/butane or process gas, according to customer preference and analysis
  • Extremely tight and long pilot flame - no automatic retraction system typically required
  • Class 1, 2 or 3 gas fired igniters according to NFPA also available
  • Also available with flexible outer tube for tilting burners

Applications

  • Ignition of medium-sized gas and oil burners in industrial furnaces and boilers

Approvals

(*) Certifications of the integrated ionisation flame monitor

(*) Certifications of the integrated ionisation flame monitor

(*) Certifications of the integrated ionisation flame monitor

Technical Data

  120 kW
Common data

Outer tube diameter

48 / 50 mm  (50 mm material stainless steel)

Flame length (depending on the gas)

max. 600 mm

Outer tube length L

240 - 15000 mm

Gas port

Rp 1/2, left or right

Gas pressure inlet

50 - 150 mbarg

Air port

Rp 1, rotatable 4 x 90°

Air pressure operating

≥10 mbarg depending on the outer tube length

Power head (not ZG0)

Ignition

5 kV against ground

Ambient temperature

-30 °C to +60 °C

Protection rating

IP 54 or IP 65

Models

without electrical components

ZG0...

with integrated spark transformer

ZT0...

with integrated spark transformer and ionisation flame monitor for intermittent operation

ZA0...

with integrated spark transformer and ionisation flame monitor for continuous operation

ZDA0...

120 kW Ex-zone 1 / 21

Common data

Outer tube length L                     

240 - 15000 mm

Gas port

Rp 3/4, top or bottom 

Gas pressure inlet

50 - 150 mbarg

Air port

Rp 1½, rotatable 4 x 90°

Air pressure operating

min. 10 mbarg, depending on the outer tube length                                                                                      

Power head

Ignition

5 kV against ground

Ambient temperature

-20 °C to +60 °C (standard), -30 °C to +75 °C (special version)                                                 

Protection rating

IP 66

Models

Heat release 120 kW

ZAVEX/0...

120 kW Ex-zone 1 / 21

Common data

Outer tube length L                     

240 - 15000 mm

Gas port

Rp 3/4, top or bottom 

Gas pressure inlet

50 - 150 mbarg

Air port

Rp 1½, rotatable 4 x 90°

Air pressure operating

min. 10 mbarg, depending on the outer tube length                                                                                      

Power head

Ignition

5 kV against ground

Ambient temperature

-20 °C to +60 °C (standard), -30 °C to +75 °C (special version)                                                 

Protection rating

IP 66

Models

Heat release 120 kW

ZAVEX/0...

120 kW Ex-zone 2 / 22

Common data

Outer tube length L

240 - 15000 mm

Gas port

Rp 1/2, left or right

Gas pressure inlet

50 - 150 mbarg

Air port

Rp 1, rotatable 4 x 90°

Air pressure operating

min. 10 mbarg, depending on the outer tube length

Power head

Ignition

5 kV against ground

Ambient temperature

-20 °C to +60 °C

Protection rating

IP 65

Models

Heat release

120 kW

with integrated spark transformer and ionisation flame monitor for intermittent operation

ZXA0...

with integrated spark transformer and ionisation flame monitor for continuous operation

ZXDA0...

120 kW

Common data

 

Outer tube diameter (stainless steel tube)

66 mm, max. 74 mm

Flame length

depending on igniter size

Outer tube length L

800 - 5000 mm

Gas pressure inlet

50 - 150 mbarg

Power head (not ZG...)

Ignition

5 kV against ground

Ambient temperature

-30 °C to +60 °C

Protection rating

IP 54 or IP 65

Models

without electrical components

ZG0F...

with integrated spark transformer

ZT0F...

with integrated spark transformer and ionisation flame monitor for intermittent operation

ZA0F...

with integrated spark transformer and ionisation flame monitor for continuous operation

ZDA0F...