AF...
Spark transformers
High tension spark transformer according to DIN EN 61558-2-3:2011 for ignition of burners and igniters, designed with separate winding and PE-terminal.
Applications
- Chemical industry
- Refineries
- Cement plants
- Waste incinerators
- Steam generators
- Heating plants
Technical Data
Type | AF 700 T 20 | AF 800 T 10 | AF 900 T 10 | AF 800 T 51 |
---|---|---|---|---|
Ignition | electrode against earth | electrode against earth | electrode against earth | electrode against earth |
Supply voltage Standard version AF... | 220-230 V AC 50/60 Hz | 220-230 V AC 50/60 Hz | 220-230 V AC 50/60 Hz | 220-230 V AC 50/60 Hz |
Supply voltage Special version AF.../00F | 110-125 V AC 50/60 Hz | 110-125 V AC 50/60 Hz | 110-125 V AC 50/60 Hz | 110-125 V AC 50/60 Hz |
Supply voltage Special version AF.../00B | 240-250 V AC 50/60 Hz | 240-250 V AC 50/60 Hz | 240-250 V AC 50/60 Hz | 240-250 V AC 50/60 Hz |
Power rating | 2 x 100 VA | 100 VA | 100 VA | 100 VA |
Ignition voltage | 2 x 5 kV | 5 kV | 5 kV | 5 kV |
Duty cycle | 15 % | 15 % | 100 % | 15 % |
Protection rating | IP 65 | IP 65 | IP 65 | IP 65 |
Dimensions W x H x D | 160 x 160 x 90 mm | 122 x 120 x 81 mm | 160 x 160 x 90 mm | 122 x 120 x 81 mm |
Weight | 4 kg | 1.9 kg | 3.5 kg | 1.9 kg |
Ambient temperature | - 20 °C to + 60 °C | - 20 °C to + 60 °C | - 20 °C to + 60 °C | - 20 °C to + 60 °C |
Enclosure material | aluminium die casting | aluminium die casting | aluminium die casting | aluminium die casting |
Mounting position | any | any | any | any |
Notes | Ignition: electrode against electrode possible | For igniters with combined spark/flame rod |