AF...

Spark transformers

High tension spark transformer according to DIN EN 61558-2-3:2011 for ignition of burners and igniters, designed with separate winding and PE-terminal.

Applications

  • Chemical industry
  • Refineries
  • Cement plants
  • Waste incinerators
  • Steam generators
  • Heating plants

Technical Data

TypeAF 700 T 20AF 800 T 10AF 900 T 10AF 800 T 51
Ignitionelectrode against earthelectrode against earthelectrode against earthelectrode against earth
Supply voltage Standard version AF...220-230 V AC
50/60 Hz
220-230 V AC
50/60 Hz
220-230 V AC
50/60 Hz
220-230 V AC
50/60 Hz
Supply voltage Special version AF.../00F110-125 V AC
50/60 Hz
110-125 V AC
50/60 Hz
110-125 V AC
50/60 Hz
110-125 V AC
50/60 Hz
Supply voltage Special version AF.../00B240-250 V AC
50/60 Hz
240-250 V AC
50/60 Hz
240-250 V AC
50/60 Hz
240-250 V AC
50/60 Hz
Power rating2 x 100 VA100 VA100 VA100 VA
Ignition voltage2 x 5 kV5 kV5 kV5 kV
Duty cycle15 %15 %100 %15 %
Protection ratingIP 65IP 65IP 65IP 65
Dimensions W x H x D160 x 160 x 90 mm122 x 120 x 81 mm160 x 160 x 90 mm122 x 120 x 81 mm
Weight4 kg1.9 kg3.5 kg1.9 kg
Ambient temperature- 20 °C to + 60 °C- 20 °C to + 60 °C- 20 °C to + 60 °C- 20 °C to + 60 °C
Enclosure materialaluminium die castingaluminium die castingaluminium die castingaluminium die casting
Mounting positionanyanyanyany
NotesIgnition: electrode against electrode possibleFor igniters with combined spark/flame rod