17.2-L-TP1412N-JB

Ignition Lances for burners and processes


  • High temperature (775 °C) ignition cable with connector and SST protection hose
  • High temperature (775 °C) thermocouple cable with connector and SST protection hose
  • SST junction box for ignition or thermocouple signal
  • Low temperature ignition cable
  • Low temperature thermocouple cable
  • Ignition and control unit

Applications

  • Burners and processes

Technical Data

Ignition lances
for burners
and processes
diameter17.2 mm17.2 mm15 mm
type17.2-L-TP1412N17.2-L-TP1412N-JB15-L-TP12-JB
designstraightstraightstraight
length L200–1000 mm:
multiple of 100 mm,
1000–2000 mm:
multiple of 100 mm,
2000–3000 mm:
200 mm intervals
200–1000 mm:
multiple of 100 mm,
1000–2000 mm:
multiple of 100 mm,
2000–3000 mm:
200 mm intervals
200–1000 mm:
multiple of 100 mm,
1000–2000 mm:
multiple of 100 mm,
2000–3000 mm:
200 mm intervals
tube material310 SST310 SST316 SST
electrical connectionM25 easy fit connector
material: 316 SST
junction box
material: aluminium
junction box
material: aluminium
mechanical connection optionnone
flange or thread
none
flange or thread
none
flange or thread
option
  • flexible lance
  • special bent shape
  • mounting adapter
  • ATEX II 2G Ex d IIC T6/T5 Gb
  • flexible lance
  • special bent shape
  • mounting adapter
  • ATEX II 2G Ex d IIC T6/T5 Gb
  • flexible lance
  • special bent shape
  • mounting adapter
  • ATEX II 2G Ex d IIC T6/T5 Gb