D-ISC 100 xx2
Universal operating unit
Universal display and operating unit in stainless steel field housing for connecting all new generation DURAG measuring systems. Ease your installation by combining several emission and flow measuring devices with only one operating unit. Realize redundant system setups with the D-ISC 100 easily and efficiently.
Overview
- Automatic sensor detection allows easy installation and setup
- Convenient operation by keypad and large display
- Quick operation, parametrisation and data transfer of the connected DURAG sensors
- Integrated power supply for one DURAG sensor
- Modular setup, expandable with expansion modules
- Combination of two D-ISC per DURAG sensor for local and remote operation (daisy chain)
- Different versions available tailored for different customer needs: compact, medium, integrated purge air blower or 19'' rack version
Applications
Suitable for all new DURAG Sensor generation for dust and volume flow measurement systems, display and operating unit for several DURAG sensors.
e.g. D-FL 100, D-FL 220, D-FL 220T, D-R 220, D-R 220T, D-R 290 2G, D-R 320, D-R 808
The universal display and operating unit D-ISC 100 can be connected to up to 8 DURAG sensors.
The large LC display simultaneously shows up to 4 measuring results.
The D-ISC 100 can either be installed close to the sensor at the stack (local) or on the control room (remote). From now on, it is possible to combine two D-ISC 100 units per DURAG sensor.
Direct access to all measuring values and parameters of the connected sensors.
The D-ISC 100 allows parameterization and maintenance of all connected sensors via the integrated keypad or a connected PC.
The D-ISC 100 also supports remote access via intranet or internet connection.
Technical Data
Conformities | CE, RoHS, VDI 4201-3, DIN EN 14181 / DIN EN ISO 14956 / EN 15267-3 (in combination with certified measuring systems) |
Certificates | CE, COC QAL1 DIN EN 14181 / DIN EN ISO 14956 / EN 15267-3 (in combination with certified measuring systems) |
Types | C: compact Version, not expandable with hardware modules M: medium Version, expandable with up to four hardware modules P: with integrated purge air blower, expandable with up to two hardware modules R: version for 19'' rack integration |
System components | D-ISC 100 universal operating unit Internal DIN rail converter Profibus DP (option) Extension module analogue IN 4 analogue inputs (option) Extension module analogue OUT 4 analogue outputs (option) Extension module digital IN 8 digital inputs (option) Extension module digital OUT 8 relais outputs (option) Software module Modbus RTU (option) Software module Modbus TCP (option) Weather protection cover (option) |
Self-check, protective functions | Password protection, self-check, sensor status monitoring |
Usage with | D-FL 100, D-FL 220, D-FL 220T, D-R 220, D-R 220T, D-R 290 2G, D-R 320, D-R 808 |
Electrical connections | 1x Mini-USB 1x DURAG device connector M23 (option) |
Digital interfaces | 1x USB (service) 1x DURAG Modbus 1x Modbus RTU / RS-485 (optional software module) 1x Profibus DP (optional DIN rail converter) 1x Modbus TCP (optional software module) |
Analogue outputs | 1x 4 … 20 mA, 400 Ohm, isolated, assignment programmable up to 17x with extension modules (option) |
Analogue inputs | None (standard) up to 16x with extension modules (option), 4 … 20 mA, 50 Ohm, zero point programmable |
Digital outputs | 2x contact NC/NO, permissible load 60 VDC / 30 VAC, 0.5 A potential free, assignment programmable up to 34x with extension modules (option) |
Digital Inputs | None (standard), up to 32x with extension modules (option), potential free, assignment programmable |
Power supply | 90 … 264 VAC, 48 … 62 Hz, 200 VA (C, M, R), type P depending on blower (200 VA or 400 VA) |
Display, status LEDs | Graphical LC display 120 x 92 mm, 5 LEDs for status display |
Operation | Keypad Service software D‑ESI 100, including remote access via web-interface (option, requires Windows-PC). Remote access via USB / Modbus RTU (option) / Modbus TCP (option) |
Purge air blower (type P only) | for D-R 320: Purge air quantity: Output regulated max. 27m³/h Inner duct pressure: -50...+50 hPa Hose connection (ID): 40 mm for D-R 808, D-R 220: Purge air quantity: stage 1 max. 15.5 m³/h, stage 2 max. 31 m³/h Inner duct pressure: stage 1 -20...+50 hPa, stage 2 -50...+50 hPa Hose connection (ID): 25 mm |
Ambient temperature (operational) | -20 … +50 °C (-4 … 122 °F) -40 … +60 °C (-40 … 140 °F) (option, except R) |
IP protection class (IEC 60529) | IP65 (C, M, P), IP20 (R) |
Relative ambient humidity | ≤ 95% RH, non-condensing. Use weather protection hood for ≥ 95% RH |
Altitude | ≤ 2000 m |
EX zone | not available |
Dimensions (hxwxd) | C: 230 x 200 x 110 mm M: 267 x 385 x 159 mm P: 410 x 400 x 240 mm R: 267 x 483 x 255 mm / 19'', 6 HE |
Weight | C: approx. 5kg M: approx. 10 kg P: approx. 20 kg R: approx. 10 kg |
Material | C: die-cast Aluminum, painted blue RAL 5017 M, P: Stainless steel 1.4301, painted blue RAL 5017 R: Aluminum, anodized |
Subject to technical modifications.