D-TB x00
Supply unit
Supply unit for power supply of all new generation DURAG measuring systems for installation at stack level. Ease your installation by combining power and purge air supply in only one unit.
Overview
- Power supply unit for one DURAG measurement system
- Version with integrated purge air blower available
- Different housings for different environmental conditions available
- Combination with D-ISC 100 possible
- Allows data transmission from DURAG measuring system to environmental data management system
Applications
Suitable for all new DURAG dust and volume flow measurement systems, also with integrated purge air supply available.
e.g. D-FL 220, D-FL 220T, D-R 220, D-R 220T, D-R 290 2G, D-R 320, D-R 808
The supply unit D-TB x00 provides power supply for one DURAG measurement system.
For several measurement systems a version with integrated purge air supply is available (e.g. D-R 220, D-R 320, D-R 808).
Connectible to DURAG universal display and operating unit
The D-TB x00 can be connected to a D-ISC 100 for setting up a network of sensors which allows parameterization and maintenance of all connected sensors via the integrated keypad or a connected PC.
Examples for installation layout of D-TB x00
D-R 320 with D-TB 200 (with integrated purge air blower)
D-R 290 with D-TB 100, connected to a D-ISC 100
Technical Data
Conformities | CE, RoHS, VDI 4201-3, DIN EN 14181 / DIN EN ISO 14956 / EN 15267-3 (in combination with certified DURAG measuring systems) |
Certificates | CE, COC QAL1 DIN EN 14181 / DIN EN ISO 14956 / EN 15267-3 (in combination with certified DURAG measuring systems) |
System components | D-TB x00 supply unit + sensor connection cable |
Usage with | D-FL 220, D-FL 220 T, D-R 220, D-R 220 T, D-R 290 2G, D-R 320, D-R 808 |
Electrical connector | 1x DURAG device connector M23 (option) |
Digital interfaces* | 1x DURAG Modbus |
Binary interface* | 1x purge air regulation (for D-TB 200) |
Outputs* | 2x digital output (NC/NO) 1x analogue output (4...20 mA) |
Power supply | 90...264 VAC, 48...62 Hz, 200 VA |
Purge air blower (D-TB 200) | for D-R 320: Purge air quantity: Output regulated max. 27 m³/h Inner duct pressure: -50...+50 hPa Hose connection (ID): 40 mm for D-R 808, D-R 220: Purge air quantity: stage 1 max. 15.5 m³/h, stage 2 max. 31 m³/h Inner duct pressure: stage 1 -50...+20 hPa, stage 2 +20...+50 hPa Hose connection (ID): 25 mm |
* terminals available for customer connection, usable in combination with DURAG measuring system
Ambient temperature (operational) | -20 ... +50 °C (-4 ... 122 °F) (in polycarbonat housing) -40 ... +60 °C (-40 ... 140 °F) (in metal housing) -40 ... +55 °C (-40 ... 131 °F) (Ex d-version) |
IP protection class (IEC 60529) | IP65 |
Relative ambient humidity | ≤ 95% RF, non-condensing |
Altitude | ≤ 2000 m (for version with integrated purge air blower) |
EX zone | for D-TB 100: Zone 1, 2 or 22, ATEX or IECEx (option) for D-TB 200: not available |
Dimensions (hxwxd) | polycarbonat housing: 160 (197) x 160 x 90 mm aluminum housing: 230 (270) x 200 x 111 mm stainless steel housing: 410 (528) x 400 (454) x 240 mm Ex d-version: 356 x 276 x 217 mm |
Weight | polycarbonat housing: approx. 2kg aluminum housing: approx. 4kg stainless steel housing: approx. 10kg Ex d-version: approx.12,5kg |
Material | D-TB 100: polycarbonat RAL 7032 or aluminum painted RAL 5017 D-TB 200: Stainless steel 1.4301, painted RAL 5017 D-TB 100 Ex: aluminum |