Product Filter
                                        
                        
                	    
            		
            	Features
- Digital real-time images with 1,400 x 1.050 pixel resolution
 - High-speed endoscope with better optical resolution than the camera used
 - Wide and flexible angle of view from 30 … 120°
 - Can be used at up to 2,000 °C in the combustion chamber
 - Can be expanded into a thermography and analysis system with the D-VTA 200 software
 - Elbowed version available
 
Benefits
- Brilliant live images from the combustion chamber around the clock
 - Detection of radiation and process fluctuations: The exposure time is not automatic and can be set by remote control, which means that radiation fluctuations in the process or flames are detected immediately
 - Wide angle of view into the combustion chamber, as the furnace camera penetrates through the furnace wall into the chamber
 - Low maintenance costs: Thanks to endoscope the furnace camera can be used with hot water or hot purge air in extreme environment
 - Flexible system: The furnace camera can be expanded into a thermography system with the thermography software D-VTA 200
 
Applications
- Cement industry: Monitoring of the sintering zone and main burner flame
 - Visualization of the combustion process in rotary kilns (e.g. hazardous waste incineration, sintering plants)
 - Visualization of combustion in power plant boilers with coal, oil or gas combustion
 
Technical Data
- Technical data
 
| Video resolution | D-FS2 ... IP04 ... : 1,280 x 960 pxD-FS2 ... IP08 ... : 1,400 x 1.050 px | 
|---|---|
| Video signal | Digital, GigE Vision, compatible with D-VT 50 and D-VTA 200 | 
| Field of view | D-FS2 VIS120… : 120°, 94°, 76° (diagonal, horizontal, vertical)D-FS2 VIS90… : 90°, 72°, 54° (diagonal, horizontal, vertical)D-FS2 VIS60… : 60°, 48°, 36° (diagonal, horizontal, vertical)D-FS2 VIS30… : 30°, 24°, 18° (diagonal, horizontal, vertical)D-FS2 VIS6060 … : Angled at 60° | 
| Temperature measurement range: | 800 … 2,000 °C using the thermography software D-VTA 200 | 
| Cooling media and purge air | D-FS2 … A60 (air-cooled):Connections: 2x G1/2″ external threadPurge air: > 10 Nm3/h at T < 45 °C or > 15Nm3/h at T < 80 °CCooling air: > 30 Nm3/h at T < 45 °C > 45Nm3/h at T < 80 °CD-FS2 … W70 (water-cooled):Connections: 3x G1/2″ external threadPurge air: > 10 Nm3/h at T < 45 °C or > 15Nm3/h at T < 80 °CCooling water: > 500 l/h at T < 80 °C and p > 2.5 bar | 
| Pressure in combustion chamber | -100 … +100 mbar | 
| Electrical connection | 12 VDC, < 10 VA (via D-SCU) | 
| Maximum permitted temperature in combustion chamber | 2,000 °C (D-FS2 … W70-xxxx)1,600°C (D-FS2 … A60-xxxx) | 
| Ambient temperature | -30 … +60 °C (optional +80 °C) | 
| Temperature monitoring | PT100 at the sensor tip | 
| Degree of protection | IP66 | 
| Connections | 1x GigE M121x 4-pin M12 | 
| Dimensions | d = 60 mm (D-FS2 … A60)d = 70 mm (D-FS2 … W70)See drawings for further dimensions | 
| Weight | 14 kg (D-FS2 … W70-700)12 kg (D-FS2 … A60-700) | 
Accessories
- Recommended
 - Optional
 
| Ethernet cable 10 Gb M12 | 
| D-FS cable 4-pin M12 | 
| D-RU | D-SCU | 
| Flange with protection tube | 
| Mounting flange | 
| Air filter system | 
							