Product Filter

EDM 180+
Approved next generation PM monitor
Provides all features of the EDM 180 plus additional USB and Ethernet interfaces. This approved environmental dust monitor is the leading product for measuring particulate matter concentration (PM10, PM2.5) in ambient air. It is in service in government networks and institutions in over 30 countries.
Functionality: Light scattering at single particles
Features
- Certificates and approvals: US-EPA, UK-MCERTS
- Real-time monitoring of PM values (PM10, PM2.5, PM1), total counts (TC), and particle number distribution
- USB and Ethernet
- Fully automatic monitoring system with remote access
- Extremely energy-efficient, low maintenance, no consumables
- No loss of semi-volatile compounds
- No radioactive source, insensitive to vibrations (applicable also in vehicles)
- Versatile data acquisition and communication (GSM data logger)
- Self-test of all optical and pneumatic components for high quality standards
- Purge air for protecting laser and detector in optical cell
- Temperature and relative humidity sensors
- Total inlet flow analyzed in optical cell
- Excellent counting statistics and reproducibility at low and high dust concentrations
Applications
- AMS for PM networks
- PM monitoring
- Epidemiological studies
- Monitoring of construction and mining sites
Technical Data
- Technical data
Measured mass fractions | PM10, PM2.5, PM1 |
---|---|
Particle size range | 0.25 … 32 μm |
Size channels | 31 |
Particle number concentration | 0 … 3,000,000 particles/l |
Reproducibility | > 97% of total measuring range |
Detection principle | Light scattering at single particles with diode laser; detection volume aerodynamically focused, no border zone error |
Optical cell | Diode laser 660 nm |
Detector | Fast signal processing, 2x 16 raw data channels |
Time resolution | 6 s (selectable storage intervals: 6 s, 1 min, 5 min, 10 min, 15 min, 30 min, 1 h) |
Sample flow rate | 1.2 l/min, ±3% constant due to self-regulation |
Internal purge air | 0.4 l/min, protection of laser optics, reference air for self-test |
Sampling inlet | Isothermal humidity extraction via Nafion membrane, sensor-controlled, without loss of semi-volatile compounds (SVC) |
Operation | Keypad, data logger or PC with GRIMM software or HyperTerminal |
Interfaces | RS-232 (GESYTEC) |
Analog input | 1 port (0 … 10 V) for auxiliary sensors |
Power supply | In: 230 V/50 Hz; optional 115 V/60 Hz |
Power consumption | 18 W standard104 W with Nafion dryer116 W maximumImax: 1.4 A |
Temperature range | -20 … +50 °C (-4 … 122 °F), non-condensing |
Absolute pressure range | 900 … 1,100 mbar, adjustable sample flow rate at high altitudes over 2,000 m |
Weather protection housing | Model 199, stand-alone, fully air-conditioned, providing space for EDM 180 and other 19″ rack instruments (see Accessories) |
Dimensions | 26.6 x 48.3 x 36.4 cm (10.5 x 19 x 14.3 in) without sampling inlet (19″ rack, 4 HU, extra 2 HU for rack adapter) |
Weight | 18 kg (39.7 lbs) without rack adapter and sampling pipe |
USP
- Certificates and approvals: US-EPA
- Real-time monitoring of PM values (PM10, PM2.5, PM1) and particle number
- "Full flow analysis" of the entire sample volume
Accessories
- Mandatory
- Optional
EDM 180+ consists of the 19-inch measuring device, a 19-inch attachment, the sampling probe and the meteorological sensor. It is offered with all necessary accessories, but can be configured by the customer (firmware, meteorological sensor etc.) |
199: Fully air-conditioned weather protection housing |
1178: Advanced GRIMM software for EDM180 |
1146: GPS sensor |
158-TRH Kit: Temperature and relative humidity sensor, with 3.5 meter cable and rain protection housing |
180DL: Data logger for our measurement equipment including the capability to transmit all data live via GSM onto a password-protected platform |
157L: Sensor for humidity, temperature and air pressure |
158L: Sensor for humidity, temperature, air pressure, wind speed and direction; requires data logger |
159L: Sensor for humidity, temperature, air pressure, wind speed and direction, and precipitation; requires data logger |