D-FS2

Furnace Sensor

The digital furnace sensor D-FS2 delivers high definition live images directly out of the combustion chamber.

The D-FS2 VIS with high resolution colour video is available as water or air cooled version.

The furnace sensor D-FS2 is designed for the use with a retraction unit. All versions can be extended with the D-VTA 200 software to a thermography and analysis system. 

Overview

  • Digital (GigE) video output
  • Water or air cooled for up to 2000°C in the combustion chamber
  • Angled version available
  • Special endoscope with high optical resolution
  • Different lengths and field of views available
  • For integration in the D-VTA 200 Thermography Analysis System

Your Benefit

  • Brilliant live images
    Special endoscope delivers the image in high resolution out of the combustion chamber to a modern digital camera - live video in real-time
  • Detection of radiation changes
    Due to the manually, remotely controlled exposure time radiation changes of the process or the flame can be detected immediately
  • High availability
    The furnace sensor is designed to be inserted continuously (24/7) in the combustion chamber
  • Safe and reliable
    In case of cooling or power failure the optional retraction unit will automatically retract the furnace sensor 
  • Flexible system
    Optional upgrade with thermography and analysis modules, adaptation to the application possible

Technical Data

Video system
Resolution GigE (Standard)

1280x960@40f/sec
Temperature measurement range
with D-VTA 200 software
800°C - 2000°C
Weight
D-FS2 ...W70-700
D-FS2 ...A60-700

app. 14kg
app. 12kg
Maximum temperature in
combustion chamber
D-FS2 ... W70-xxxx
D-FS2 ... A60-xxxx


up to 2000°C
up to 1600°C
Temperature monitoring
at endoscope tip
PT100
Ambient temperature (operational)-30 ... +60°C
Furnace pressure-100 ... +100mbar
Cooling media (water cooled version)
cooling water quantity
purge air quantity

>500l/h
>15Nm3/h
Cooling media (air cooled version)
cooling air quantity
purge air quantity

>35Nm3/h
>15Nm3/h
IP protection class (IEC 60529)IP66

Subject to technical modifications.

Video system
Resolution Ethernet

320x240@30f/sec
Measurement range
with D-VTA 200 software
250°C - 1200°C
Weight
D-FS2 ...W70-700
D-FS2 ...A60-700

app. 14kg
app. 12kg
Maximum temperature
in combustion chamber 
D-FS2 ... W70-xxxx
D-FS2 ... A60-xxxx


up to 2000°C
up to 1400°C
Temperature monitoring
at endoscope tip
PT100
Maximum ambient temperature -30 ... +60°C
Furnace pressure-100 ... +100mbar
Cooling media (water cooled version)
Amount of cooling water
Amount of purge air
Air for Vortex cooler

>500l/h
>15Nm3/h
15Nm3/h
Cooling media (air cooled)
Amount of cooling air
Amount of purge air
Air for Vortex cooler

>35Nm3/h
>15Nm3/h
15Nm3/h
IP-RatingIP66

Accessories

  • Retraction unit (D-RU2 A60/W70)
  • Sensor control unit for power supply and signal transmission (D-SCU xx)
  • Welding plate for retraction unit
  • Mounting flange for fixed installation without retraction unit
  • Two stage air filter system for purge and cooling air